VI EN
Rittal

SK 3110000 | Controller temperature Rittal | Genuine

BrandRittal
SKUSK 3110000 - 3110.000
WarrantyThermostat Enclosure internal thermostat
Commitment100% genuine products
DescriptionUnit control temperature SK, unit control temperature inside enclosure equipment device, 24-230 V, 1~, 24-60 V (DC), Color RAL 7035, Dimensions (W x H x D): 71 x 71 x 33,5 mm

REQUEST A QUOTE

Technical information

Size size: 71mm x 71mm x 33,5mm (W x H x D)

Weight quantity: 0,095 kg

Type contact contact switching circuit one pole use work contact ngắt nhanh.
Load contact for allowed Type 5 – 3 (heater ấm) AC 10 (4) A (load sensor application ở cos φ = 0,6)
Type 5- 4 (work cooling): AC 5 (4) A (load sensor application ở cos φ = 0,6)/ DC = maximum 30 W

Electrical voltage operation rated

24 V - 230 V, 1~
24 V - 60 V (DC)

Chênh lệch switching circuit range 1 K ± 0,8 K

Customers refer to the information product according to line link lower (source power: https://www.rittal.com)

SERVICES & SUPPORT

Rittal Enclosure Cooling Unit Consulting & Installation – Safe, Efficient and Optimized Cooling Solutions In industrial environment modern, work ensure conditions temperature stability in enclosure electrical, control cabinet is important factor to maintain for the continuous operation and safety of system system. Enclosure cooling unit Rittal – leading German brand – is solution optimal helps maintain precise temperature control, protection electronic components from overheating and extend service life equipment device. RITTAL Enclosure Cooling Unit Error Code Table In order to help you fix the troubleshooting of RITTAL cooling units with Comfort Controller. A more detailed explanation of the system messages are shown on the display screen via the displays from A1 to A20 as the table below: Common RITTAL Enclosure Cooling Solutions Solution information use work cooling enclosure electrical of Rittal includes: Fan & Filter (Fan & Panel filter), system system Cooling Unit (Machine cooling) Quick Maintenance Process for RITTAL Cooling Units in Clean, Low-Dust Environments Sequence of maintenance measures: – Check the level of dirt. – Filter soiling? Replace the filter if necessary. – Cooling membranes soiled? Clean if necessary. – Activate test mode; cooling function OK? – Check noise generation of compressor and fans. Periodic Cleaning and Maintenance Service for Rittal Enclosure Cooling Units Why right maintenance machine cooling for industrial enclosure periodically?