DescriptionCooling unit SK Blue e+, wall-mounted, power 2kW, electrical voltage 110-240V, 1~, 380-480V, 3~, 50-60 Hz, enclosure sheet steel, dimensions (W x H x D): 450 x 1600 x 294 mm

REQUEST A QUOTE

Technical information

Size size: 450 x 1600 x 294 mm (W x H x D)

Net weight: 55,2kg

Total weight quantity: 73,8kg

Material

Sheet steel

Range temperature degree operation

-20°C...60°C

Total power work cooling according to standard standard DIN EN 14511

Power work cooling L35 L35/50 Hz: 2 kW
Power work cooling L35 L35/60 Hz: 2 kW
Power work cooling L35 L50/50 Hz: 1,29 kW
Power work cooling L35 L50/60 Hz: 1,29 kW

Electrical voltage operation rated

110 V - 240 V, 1~, 50 Hz/60 Hz
380 V - 480 V, 3~, 50 Hz/60 Hz

Power input rated

0,73 kW

Supply degree protection according to standard standard IEC 60 529

Circuit nội unit IP 55

Supply degree protection NEMA

UL Type 12
UL Type 3R

Customers refer to the information product according to line link lower (source power: https://www.rittal.com)

SK 3186930 | Enclosure cooling unit Wall-mounted Blue e+ 2.kW Rittal | Genuine

SERVICES & SUPPORT

Rittal Enclosure Cooling Unit Consulting & Installation – Safe, Efficient and Optimized Cooling Solutions In industrial environment modern, work ensure conditions temperature stability in enclosure electrical, control cabinet is important factor to maintain for the continuous operation and safety of system system. Enclosure cooling unit Rittal – leading German brand – is solution optimal helps maintain precise temperature control, protection electronic components from overheating and extend service life equipment device. Common RITTAL Enclosure Cooling Solutions Solution information use work cooling enclosure electrical of Rittal includes: Fan & Filter (Fan & Panel filter), system system Cooling Unit (Machine cooling) RITTAL Enclosure Cooling Unit Error Code Table In order to help you fix the troubleshooting of RITTAL cooling units with Comfort Controller. A more detailed explanation of the system messages are shown on the display screen via the displays from A1 to A20 as the table below: Quick Maintenance Process for RITTAL Cooling Units in Clean, Low-Dust Environments Sequence of maintenance measures: – Check the level of dirt. – Filter soiling? Replace the filter if necessary. – Cooling membranes soiled? Clean if necessary. – Activate test mode; cooling function OK? – Check noise generation of compressor and fans. Periodic Cleaning and Maintenance Service for Rittal Enclosure Cooling Units Why right maintenance machine cooling for industrial enclosure periodically?