VI EN
Rittal

SK 3201200 | Enclosure cooling unit Thermoelectric 80W Rittal | Genuine

BrandRittal
SKUSK 3201200 - 3201.200
Commitment100% genuine products
DescriptionUnit work cooling temperature electrical SK, 80/80 W, 100-240 V, 1~, 50/60 Hz, Dimensions (W x H x D): 125 x 400 x 155 mm

REQUEST A QUOTE

Technical information

Size size: 125 x 400 x 155 mm (W x H x D)

Net weight: 4,05kg

Total weight quantity: 4,38kg

Material

Aluminium, plated anod

Range temperature degree operation

-30°C...55°C

Total power work cooling according to standard standard DIN EN 14511

Power work cooling L35 L35/50 Hz: 80 W
Power work cooling L35 L35/60 Hz: 80 W

Electrical voltage operation rated

100V - 240V, 1~, 50 Hz/60 Hz

Rated current maximum

1.9A

Supply degree protection according to standard standard IEC 60 529

Circuit external IP 34
Circuit nội unit IP 54

Customers refer to the information product according to line link lower (source power: https://www.rittal.com)

SK 3201200 | Enclosure cooling unit Thermoelectric 80W Rittal | Genuine

SERVICES & SUPPORT

Rittal Enclosure Cooling Unit Consulting & Installation – Safe, Efficient and Optimized Cooling Solutions In industrial environment modern, work ensure conditions temperature stability in enclosure electrical, control cabinet is important factor to maintain for the continuous operation and safety of system system. Enclosure cooling unit Rittal – leading German brand – is solution optimal helps maintain precise temperature control, protection electronic components from overheating and extend service life equipment device. RITTAL Enclosure Cooling Unit Error Code Table In order to help you fix the troubleshooting of RITTAL cooling units with Comfort Controller. A more detailed explanation of the system messages are shown on the display screen via the displays from A1 to A20 as the table below: Common RITTAL Enclosure Cooling Solutions Solution information use work cooling enclosure electrical of Rittal includes: Fan & Filter (Fan & Panel filter), system system Cooling Unit (Machine cooling) Quick Maintenance Process for RITTAL Cooling Units in Clean, Low-Dust Environments Sequence of maintenance measures: – Check the level of dirt. – Filter soiling? Replace the filter if necessary. – Cooling membranes soiled? Clean if necessary. – Activate test mode; cooling function OK? – Check noise generation of compressor and fans. Periodic Cleaning and Maintenance Service for Rittal Enclosure Cooling Units Why right maintenance machine cooling for industrial enclosure periodically?