VI EN
Rittal

SK 3305544 | Enclosure cooling unit Wall-mounted Blue e 1.6kW Rittal | Genuine

BrandRittal
SKUSK 3305544 - 3305.544
Commitment100% genuine products
DescriptionUnit work cooling SK Blue e, wall-mounted, NEMA 4X, 1.6kW, 400-460V, 3~, 50/60 Hz, Stainless steel, Dimensions (W x H x D): 405 x 1020 x 358 mm

REQUEST A QUOTE

Technical information

Size size: 405 x 1020 x 358 mm (W x H x D)

Net weight: 58kg

Total weight quantity: 63kg

Material

Stainless steel 1.4301 (AISI 304)

Range temperature degree operation

10°C...55°C

Total power work cooling according to standard standard DIN EN 14511

Power work cooling L35 L35/50 Hz: 1,6 kW
Power work cooling L35 L35/60 Hz: 1,61 kW
Power work cooling L35 L50/50 Hz: 1,1 kW
Power work cooling L35 L50/60 Hz: 1,25 kW

Electrical voltage operation rated

400 V, 3~, 50 Hz
460 V, 3~, 60 Hz

Rated current maximum

2.5A/ 50Hz
2.8A/ 60Hz

Supply degree protection NEMA

NEMA 4X

Supply degree protection according to standard standard IEC 60 529

Circuit external IP 34
Circuit nội unit IP 55

Customers refer to the information product according to line link lower (source power: https://www.rittal.com)

SK 3305544 | Enclosure cooling unit Wall-mounted Blue e 1.6kW Rittal | Genuine

SERVICES & SUPPORT

Rittal Enclosure Cooling Unit Consulting & Installation – Safe, Efficient and Optimized Cooling Solutions In industrial environment modern, work ensure conditions temperature stability in enclosure electrical, control cabinet is important factor to maintain for the continuous operation and safety of system system. Enclosure cooling unit Rittal – leading German brand – is solution optimal helps maintain precise temperature control, protection electronic components from overheating and extend service life equipment device. Common RITTAL Enclosure Cooling Solutions Solution information use work cooling enclosure electrical of Rittal includes: Fan & Filter (Fan & Panel filter), system system Cooling Unit (Machine cooling) RITTAL Enclosure Cooling Unit Error Code Table In order to help you fix the troubleshooting of RITTAL cooling units with Comfort Controller. A more detailed explanation of the system messages are shown on the display screen via the displays from A1 to A20 as the table below: Quick Maintenance Process for RITTAL Cooling Units in Clean, Low-Dust Environments Sequence of maintenance measures: – Check the level of dirt. – Filter soiling? Replace the filter if necessary. – Cooling membranes soiled? Clean if necessary. – Activate test mode; cooling function OK? – Check noise generation of compressor and fans. Periodic Cleaning and Maintenance Service for Rittal Enclosure Cooling Units Why right maintenance machine cooling for industrial enclosure periodically?