VI EN
RITTAL

SV 9343000 | Fuse ngắt circuit NH Rittal | Genuine

BrandRITTAL
SKUSV 9343000 9343.000
Warranty9343000 NH fuse-switch disconnector, size 00, 160 A, 690 V, 3-pole, box terminal
Commitment100% genuine products
DescriptionIndustrial switch ngắt circuit fuse SV NH, cỡ 00, 160A, 690V, 3 pole, connector box

REQUEST A QUOTE

Technical information

product this will is replace voltage by:9362030 - fuse ngắt circuit RiLineX NH

Net weight: 0,84 kg

Total weight quantity: 0,92 kg

Material:Material polyamide, flame-retardant according to standard standard UL 94.

Line conductor contact: Copper electrical distribution, silver-plated.

Current electrical operation rated maximum

160A

Electrical voltage operation rated

690V, 3~

Number quantity pole

3

Detail area conductor round

4 - 95 mm²

for system system bar with distance center to center

60mm

Customers refer to the information product according to line link lower (source power: https://www.rittal.com)

SV 9343000 | Fuse ngắt circuit NH Rittal | Genuine

SERVICES & SUPPORT

Rittal Enclosure Cooling Unit Consulting & Installation – Safe, Efficient and Optimized Cooling Solutions In industrial environment modern, work ensure conditions temperature stability in enclosure electrical, control cabinet is important factor to maintain for the continuous operation and safety of system system. Enclosure cooling unit Rittal – leading German brand – is solution optimal helps maintain precise temperature control, protection electronic components from overheating and extend service life equipment device. Common RITTAL Enclosure Cooling Solutions Solution information use work cooling enclosure electrical of Rittal includes: Fan & Filter (Fan & Panel filter), system system Cooling Unit (Machine cooling) RITTAL Enclosure Cooling Unit Error Code Table In order to help you fix the troubleshooting of RITTAL cooling units with Comfort Controller. A more detailed explanation of the system messages are shown on the display screen via the displays from A1 to A20 as the table below: Quick Maintenance Process for RITTAL Cooling Units in Clean, Low-Dust Environments Sequence of maintenance measures: – Check the level of dirt. – Filter soiling? Replace the filter if necessary. – Cooling membranes soiled? Clean if necessary. – Activate test mode; cooling function OK? – Check noise generation of compressor and fans. Periodic Cleaning and Maintenance Service for Rittal Enclosure Cooling Units Why right maintenance machine cooling for industrial enclosure periodically?